<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-03 23-44-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 68 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz 83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19035 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,9 dBr 2,25 dBr 4,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Kvintetto Nro 6 huilulle ja jousille D-Duuri G 430 (Boccherini) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2024/08/03 23.43.41 Total samples: 19035 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,0 dBr MIN: 0,9 dBr AVE: 2,25 dBr % above 12,2 dBr: 0,0 Last value: 1,6 dBr (2024/08/03 23.43.41) 23.30 23.32 23.34 23.36 23.38 23.40 23.42 0 2 4 Pm [dBr]